DELTA CARGO Spray Booth
The Delta Cargo pulls clean air from the upper fully filtered ceiling and exhausts the air through both lower side plenums.
CODE COMPLIANCE: RGI manufactures and designs paint booths to meet applicable industry codes and standards. Please be aware that local requirements may vary from national codes. RGI recommends consulting local authorities before purchasing paint booths.
- Reference NFPA 33 and Chapter 24 of the International Fire Code (IFC) for spray applications using flammable and combustible materials
- Reference NFPA 86 and Chapter 30 of the IFC for curing and drying applications
- Many components and product lines are ETL and ETL-C listed. The ETL or ETL-C mark is proof of compliance with North American safety standards, including UL, NFPA, OSHA and more
- A UL or CUL listing verifies that Underwriters Laboratories has tested RGI’ product and determined that it meets their stringent safety and performance requirements
Specifications (increments every 5' available)
40' Model
- Outside Dim. 20'4" Wide x 40'-4" Long x 17'-6" High
- Work Inside Dim. 16' Wide x 40’ 6”' Long x 16' High
45' Model
- Outside Dim. 20'4" Wide x 45'-4" Long x 17'-6"
- High Work Inside Dim. 16' Wide x 45’ 6”' Long x 16' High
50' Model
- Outside Dim. 20'4" Wide x 50'-4" Long x 17'-6"
- High Work Inside Dim. 16' Wide x 50’ 6”' Long x 16' High
General Specifications
Air Flow Description: Side downdraft paint booths are an economical solution for shops that aren’t able to install a pit. Air comes into the booth through a full-length, filtered ceiling plenum, and flows downward over the product. When air reaches the floor, it is pulled into floor-level filtered exhaust plenums on both sides of the booth.
Construction: All of our single wall booths are made with premium 18 ga. Zinc galvanized steel panels, companion flanged and pre-punched at 6" on center for easy assembly with 1/4" nuts and bolts. Single Wall. Better airflow, lighting, and strength because of gabled roof design
Top-Quality Hardware RGI uses high-quality hardware — including heavy-duty latches, long-lasting brass bushings, durable hollow rubber seals and sturdy handles — to ensure ease of use and many years of reliable service. Hinges and latches stay secured and are fully adjustable for a perfect fit. Our weld-free designs prevent against weak points and corrosion, making for a sturdy, long-lasting booth
Detail Spec Included
- 18 gauge prime quality galvanized Air-tight steel panels
- (1) Set of DOUBLE WALL TRI-FOLD drive-in doors with observation windows, opening Dim. 16' high x 12' wide
- (1) Side access man door - Dim. 3'x7' with observation windows
- LED (standard) 4’ Long, 4 tube LED T8 light fixtures 120v.
- (2) 30" Dia. Tube-axial fan with aluminum spark-proof blades belt drive exhaust fan
- (2) 3hp 3ph Belt-drive motor 208-230/460v. 60 hz
- (1) Mark Dwyer manometer kit defines air flow pressure
- (30) Exhaust filters w/ (30) exhaust filter grids
- (12) Intake filter pads 37” x 117” x 2” Ceiling Diffusion Media is a 1” thick, scrim backed
- (1) Hardware set for assembly; nuts & bolts, screws, door foam seal, door latches, door handles, and flat rubber for the bottom of entry doors for a tight seal. Single Wall
Optional Product
- Powder coat ultra white inside and out of the spray booth. cover all wall panels, door frames, floor channels, and ceiling panels.
- Controls for spray booth, mag start for the motor with on and off switch and reset. Interlock valve with door limit switches for on and off on spray cycle
- 2-24” Ducting kit for spray booth exhaust system. (2) Plain duct, (1) Service door duct, (1) Flashing for roof, and (1) damper cap
- 1 Phase Upgrade
- Fire Suppression System
- Heating for your Spray Booth
- Drive Through Doors
Downloads
All paint spray booths manufactured by RGI Mfg. Co. (RGI) are warranted by RGI, against defects in workmanship for materials under normal use for one year after the date of purchase from RGI. Any part which is determined by RGI to be defective in material or workmanship and is returned to RGI, shipping cost prepaid, will be, as the exclusive remedy, repaired or replaced at RGI’s option.
LIMITATIONS OF LIABILITY
Any liability of consequential and incidental damages is expressly disclaimed. RGI’s liability in all events is limited to, and shall not exceed, the replacement price of the part.
PRODUCT SUITABILITY
All states and localities have codes and regulations governing the construction, installation and/or use of paint spray booths, which may be interpreted differently from those in neighboring areas. While RGI attempts to assure that it’s spray booths comply with such codes, it cannot guarantee compliance, and cannot be responsible for how the spraybooth is installed or used. Before the purchase and use of a spray booth, please review the spray booth application, and national and local codes and regulations, and be sure that the product, installation and use comply with them.
FREIGHT LOSS OR DAMAGE POLICY
Unless otherwise specified, RGI accepts no responsibility for loss or damages to products shipped from RGI unless said products are shipped freight prepaid by RGI. Exception: If it is determined by RGI that loss or damage occurred as a result of negligence on the part of RGI, RGI will replace the lost or damaged articles. If such a determination is made by RGI, replacement of lost or damaged articles will occur only after receipt of a written request, from the purchaser.